&#x1F9ED; REBEL Rundown &#x1F5DD;&#xFE0F; Key Points &#x1F4A8; Peak vs. Plateau Pressures: PIP reflects total airway resistance and compliance, while Pplat isolates alveolar compliance&#x2014;elevations in both suggest decreased lung compliance (e.g., ARDS, pulmonary edema, pneumothorax).&#x1F9F1; PEEP Protects Alveoli: Maintains alveolar recruitment and prevents collapse; typical range 5&#x2013;8 cmH&#x2082;O, but higher levels may benefit moderate&#x2013;severe ARDS.&#xFE0F; Driving Pressure (&#x394;P = Pplat &#x2212; PEEP): Lower &#x394;P reduces atelectrauma and improves outcomes; optimize by adjusting PEEP thoughtfully.&#x1F4A5; Prevent VILI: Keep Pplat < 30 cmH&#x2082;O, use low tidal volumes (6 mL/kg IBW), and monitor for barotrauma, volutrauma, atelectrauma